TAS250-EW Easywire Three Phase Measuring Current Transformer

  • Ranges: 800 to 1600 A (330 mV Secondary).
  • Cable aperture : 3 @ 54 x 50 mm.
  • Accuracy Class 1.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Weight : 1200 g.

TAS248-EW Easywire Three Phase Measuring Current Transformer

  • Ranges: 250 to 630 A (330 mV Secondary).
  • Cable aperture : 3 @ 31 x 31 mm.
  • Accuracy Class 1.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Weight : 680 g.
    Dimensions
    H=90, W=140, D=52 mm

TAS242-EW Easywire Three Phase Measuring Current Transformer

  • Ranges: 60 to 250 A (330 mV Secondary).
  • Cable aperture : 3 @ 21 x 25 mm.
  • Accuracy Class 1.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Weight: 550 g.

Dimensions
H=80, W=105, D=86mm

TAS240-EW Easywire Three Phase Measuring Current Transformer

  • Ranges: 60 to 160 A (330 mV Secondary).
  • Cable aperture : 3 @ 15.5 x 30 mm.
  • Accuracy Class 1.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Weight : 500 g.

Dimensions
H=80, W=75, D=75

TAS-250 Three Phase Current Transformer RI-CT250

  • Three Phase Measuring Current Transformers.
  • Primary Current Ratios: 630 to 1600 A.
  • Secondary Current: 5 A.
  • Cable Aperture: 3 @ 54 x 50 mm with a 70 mm Hole Aperture Centre.
  • Class Accuracy: Cl0.5, Cl1 and Cl3.
  • Reference Standards : EN60044–1.
  • Temperature Range : Working –25 to +50˚C, relative humidity 85%.
  • Frequency : 47…63 Hz (400 Hz on request).
  • System Voltage : 720 V max.
  • Test Voltage : 3 kV for 1 minute.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Secondary terminals M4 Screws.
  • Sealable terminal cover included.
  • Weight : 1200 g.

TAS-248 Three Phase Current Transformer RI-CT248

  • Three Phase Measuring Current Transformers.
  • Primary Current Ratios: 250 to 630 A.
  • Secondary Current: 5 A.
  • Cable aperture : 3 @ 31 x 31 mm with a 45 mm Hole Apeture Centre.
  • Class Accuracy: Cl0.5, Cl1 and Cl3.
  • Reference Standards : EN60044–1.
  • Temperature Range : Working –25 to +50˚C, relative humidity 85%.
  • Frequency : 47…63 Hz (400 Hz on request).
  • System Voltage : 720 V max.
  • Test Voltage : 3 kV for 1 minute.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Secondary terminals M4 Screws.
  • Sealable terminal cover included.
  • Weight : 680 g.

TAS-242 Three Phase Current Transformer RI-CT242

  • Three Phase Measuring Current Transformers.
  • Primary Current Range: 60 to 250 A.
  • Secondary Current Ratios: 5 A.
  • Cable aperture : 3 @ 21 x 25 mm with a 35 mm Hole Apeture Centre.
  • Class Accuracy: Cl0.5, Cl1 and Cl3.
  • Reference Standards : EN60044–1.
  • Temperature Range : Working –25 to +50˚C, relative humidity 85%.
  • Frequency : 47…63 Hz (400 Hz on request).
  • System Voltage : 720 V max.
  • Test Voltage : 3 kV for 1 minute.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Secondary terminals M4 Screws.
  • Sealable terminal cover included.
  • Weight : 550 g.

TAS-240 Three Phase Current Transformer RI-CT240

  • Three Phase Measuring Current Transformers.
  • Primary Current Range: 60 to 200 A.
  • Secondary Current Ratios: 5 A.
  • Cable aperture : 3 @ 15.5 x 30 mm with a 25 mm Hole Aperture Centre.
  • Class Accuracy Cl0.5, Cl1 and Cl3.
  • Reference Standards : EN60044–1.
  • Temperature Range : Working –25 to +50˚C, relative humidity 85%.
  • Frequency : 47…63 Hz (400 Hz on request).
  • System Voltage : 720 V max.
  • Test Voltage : 3 kV for 1 minute.
  • Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94.
  • Secondary terminals M4 Screws.
  • Sealable terminal cover included.
  • Weight : 500 g.